MPI_Get_processor_name

Langue: en

Version: 173358 (fedora - 06/07/09)

Autres sections - même nom

Section: 4 (Pilotes et protocoles réseau)

NAME

MPI_Get_processor_name - Gets the name of the processor

SYNOPSIS

 int MPI_Get_processor_name( char *name, int *resultlen )
 

OUTPUT PARAMETERS

name
- A unique specifier for the actual (as opposed to virtual) node. This must be an array of size at least MPI_MAX_PROCESSOR_NAME .
resultlen
- Length (in characters) of the name

NOTES

The name returned should identify a particular piece of hardware; the exact format is implementation defined. This name may or may not be the same as might be returned by gethostname , uname , or sysinfo .

THREAD AND INTERRUPT SAFETY

This routine is thread-safe. This means that this routine may be safely used by multiple threads without the need for any user-provided thread locks. However, the routine is not interrupt safe. Typically, this is due to the use of memory allocation routines such as malloc or other non-MPICH runtime routines that are themselves not interrupt-safe.

NOTES FOR FORTRAN

All MPI routines in Fortran (except for MPI_WTIME and MPI_WTICK ) have an additional argument ierr at the end of the argument list. ierr is an integer and has the same meaning as the return value of the routine in C. In Fortran, MPI routines are subroutines, and are invoked with the call statement.

All MPI objects (e.g., MPI_Datatype , MPI_Comm ) are of type INTEGER in Fortran.

In Fortran, the character argument should be declared as a character string of MPI_MAX_PROCESSOR_NAME rather than an array of dimension MPI_MAX_PROCESSOR_NAME . That is,

 character*(MPI_MAX_PROCESSOR_NAME) name
 

rather than

 character name(MPI_MAX_PROCESSOR_NAME)
 

The two

The sizes of MPI strings in Fortran are one less than the sizes of that string in C/C++ because the C/C++ versions provide room for the trailing null character required by C/C++. For example, MPI_MAX_ERROR_STRING is mpif.h is one smaller than the same value in mpi.h . See the MPI-2 standard, sections 2.6.2 and 4.12.9.

ERRORS

All MPI routines (except MPI_Wtime and MPI_Wtick ) return an error value; C routines as the value of the function and Fortran routines in the last argument. Before the value is returned, the current MPI error handler is called. By default, this error handler aborts the MPI job. The error handler may be changed with MPI_Comm_set_errhandler (for communicators), MPI_File_set_errhandler (for files), and MPI_Win_set_errhandler (for RMA windows). The MPI-1 routine MPI_Errhandler_set may be used but its use is deprecated. The predefined error handler MPI_ERRORS_RETURN may be used to cause error values to be returned. Note that MPI does not guarentee that an MPI program can continue past an error; however, MPI implementations will attempt to continue whenever possible.

MPI_SUCCESS
- No error; MPI routine completed successfully.

LOCATION

getpname.c