usbmon

Langue: en

Version: 175187 (fedora - 06/07/09)

Section: 8 (Commandes administrateur)

NAME

usbmon - monitor USB traffic

SYNOPSIS

usbmon [ -i bus_num ] [ -s length ] [ -f0 | -fu | -fh ] [ -a0 | -a1 ]

DESCRIPTION

usbmon allows to capture USB traffic for analysis in the manner similar to tcpdump (8).

To make use of this program, you need to have a Linux kernel which supports the binary "usbmon" interface (e.g., Linux kernel 2.6.20 or newer).

OPTIONS

-i
Listen on bus_num. If unspecified, usbmon attempts to listen on the pseudo-bus number zero, which is supposed to capture all packets on all buses. The default is a convenient mode because the user does not have to figure out the bus number where a specific device is attached. Also, listening on pseudo-bus zero allows to capture events which happen when a bus is initialized.

However, it may be necessary to specify a specific bus number to tap. Kernels before 2.6.22 do not implement the pseudo-bus zero at all. Performance of USB stack and the usbmon is greater when a specific bus is monitored. In such case, the desired bus number may be determined by examining the output of lsusb(8).

-s
Set the maximum length of USB data to print. The default is to print 32 bytes just like the kernel's text interface would. The capture size is automatically adjusted to match unless set explicitly.
-f
Select the output format as one of: '0' for legacy format, 'u' for so-called "1u" format, 'h' for "human-readable" format. The human-readable format is the default. Also, it changes over time, so programs should parse the "1u" format.

Selecting the 1u format forces usbmon to use the API which may not be available in the kernel before version 2.6.22.

-a
Force the binary API version to use: '0' for the legacy API in kernel 2.6.20 and up, '1' for the newer API in kernels after 2.6.22. Selection of output format may force the API to the minimum required to support the format. In general, this option is only used when testing the kernel component of usbmon.

OUTPUT FORMAT

The output of usbmon contains one text line per an event. The event corresponds to I/O operations on the boundary of Host Controller Driver (HCD). This includes events of the following types: Submission, Callback, Error. Every line consists of whitespace separated words. The number or position of words may depend on the event type, but there is a set of words, common for all types.

Most commonly used format is the human-readable format. Its words, from left to right, are:

- URB Tag. A single URB generates several monitoring events during its life cycle. The tag allows to corellate events with the URB. Tag is usually derived from a kernel mode address. Human-readable format shortens the tag to make the output more readable, so it's not the complete address.

- Timestamp. It consistes of the number of seconds, period, and the fraction in microseconds.

- Event Type. This type refers to the format of the event, not URB type. Available types are: S - submission, C - callback, E - submission error.

- "Pipe word" (the name is historical and has nothing to do with pipes). This is a composite word. It consists of four fields, separated by colons: URB type and direction, Bus number, Device address, Endpoint number. Type and direction are encoded with two bytes in the following manner:


    Ci Co   Control input and output
    Zi Zo   Isochronous input and output
    Ii Io   Interrupt input and output
    Bi Bo   Bulk input and output

The address information fields may contain leading zeros. If the bus is specified with -i, the Bus number field is redundant, but is kept for the ease of parsing.

- Status word. This word may have several fields, depending on the transfer type. Most transfers only have the status field. Interrupt and Isochronous transfers add an interval. For Isochronous, start frame and error count may be present. For callback and error events, the status field contains an integer number, which represents a "status" field of the URB. For a submission event, status makes no sense, so the field contains a single dash.

Control submissions are an exception, because they may have a setup packet. In such case, the event contains a letter in place of the status word. The letter is called "setup tag".

- Setup packet, if present, consists of 5 words: one of each for bmRequestType, bRequest, wValue, wIndex, wLength, as specified by the USB Specification 2.0. These words are safe to decode if Setup Tag was 's'. Otherwise, the setup packet was present, but not captured, and the fields contain filler.

- The number of isochronous frame descriptors (optional).

- Isochronous descriptors (optional). This is a new feature of usbmon, poorly understood, and poorly documented. XXX

- Data Tag

- Data (if Data Tag is '=')

The following is the list of words for the legacy format, from left to right:

- URB Tag. This is normally a kernel mode address of the URB structure.

- Timestamp in microseconds, a decimal number. The timestamp's resolution depends on available clock, and so it can be much worse than a microsecond (if the implementation uses jiffies, for example). The number of microseconds is usually truncated, so it can wrap if usbmon runs long enough.

- Event Type. This type refers to the format of the event, not URB type. Available types are: S - submission, C - callback, E - submission error.

- "Pipe". The pipe concept is deprecated. This is a composite word, used to be derived from information in pipes. It consists of three fields, separated by colons: URB type and direction, Device address, Endpoint number. Type and direction are encoded with two bytes in the following manner:


    Ci Co   Control input and output
    Zi Zo   Isochronous input and output
    Ii Io   Interrupt input and output
    Bi Bo   Bulk input and output

Device address and Endpoint number are 3-digit and 2-digit (respectively) decimal numbers, with leading zeroes.

- URB Status. In most cases, this field contains a number, sometimes negative, which represents a "status" field of the URB. This field makes no sense for submissions, but is present anyway to help scripts with parsing. When an error occurs, the field contains the error code. In case of a submission of a Control packet, this field contains a Setup Tag instead of an error code. It is easy to tell whether the Setup Tag is present because it is never a number. Thus if scripts find a number in this field, they proceed to read Data Length. If they find something else, like a letter, they read the setup packet before reading the Data Length.

- Setup packet, if present, consists of 5 words: one of each for bmRequestType, bRequest, wValue, wIndex, wLength, as specified by the USB Specification 2.0. These words are safe to decode if Setup Tag was 's'. Otherwise, the setup packet was present, but not captured, and the fields contain filler.

- Data Length. For submissions, this is the requested length. For callbacks, this is the actual length.

- Data tag. The usbmon may not always capture data, even if length is nonzero. The data words are present only if this tag is '='.

- Data words follow, in big endian hexadecimal format. Notice that they are not machine words, but really just a byte stream split into words to make it easier to read. Thus, the last word may contain from one to four bytes. The length of collected data is limited (see the -s parameter) and can be less than the data length report in the Data Length word.

FILES

/proc/devices
This file is read to determine the major of /dev/usbmonN if such node does not exist in the system.
/dev/usbmonN
The usbmon attempts to open /dev/usbmon{N}, where N is the bus number. If the node does not exist, usbmon creates it.

SEE ALSO

lsusb(8)

AUTHOR

Pete Zaitcev, <zaitcev@redhat.com>.