NAME
gpiv_recimg - captures images from a IIDC-compliant camera with IEE1394 connection.SYNOPSIS
gpiv_recimg [-f filename] [-h | --help] [-v | --version] [-V | --verbose] [-x | --x_corr] < stdin > stdout
DESCRIPTION
gpiv_recimg records image pairs for Particle Image velocimetry (PIV). The code supports IIDC-compliant cameras that are connected to the computer with IEEE1394. Such an image pair may be analysed by gpiv_rr in the cross-correlation mode for PIV.
This program uses the IMG parameters. The command line options are explained below.
Options
-f filename Overrides stdin and stdout with filename. The filename has to be given without its .r extension. Output will be written to filename.r.- -h | --help
- On-line help.
- -v | --version
- Print version information on standard output, then exit successfully.
- -V | --verbose
- program behaves more verbose during operation showing what is going on
- -x | --x_corr
- Records two succesive image frames for cross-correlation and stores as a single image. In this case, gpiv_combing is not needed.
SEE ALSO
gpivtoolsAUTHOR
Gerber Van der GraafBUGS
The program is still in a very prelimary state.Contenus ©2006-2024 Benjamin Poulain