Rechercher une page de manuel
struct_regulator_ops
Langue: en
Version: October 2010 (fedora - 01/12/10)
Section: 9 (Appels noyau Linux)
NAME
struct_regulator_ops - regulator operations.SYNOPSIS
struct regulator_ops { int (* list_voltage) (struct regulator_dev *, unsigned selector); int (* set_voltage) (struct regulator_dev *, int min_uV, int max_uV); int (* get_voltage) (struct regulator_dev *); int (* set_current_limit) (struct regulator_dev *,int min_uA, int max_uA); int (* get_current_limit) (struct regulator_dev *); int (* enable) (struct regulator_dev *); int (* disable) (struct regulator_dev *); int (* is_enabled) (struct regulator_dev *); int (* set_mode) (struct regulator_dev *, unsigned int mode); unsigned int (* get_mode) (struct regulator_dev *); int (* enable_time) (struct regulator_dev *); int (* get_status) (struct regulator_dev *); unsigned int (* get_optimum_mode) (struct regulator_dev *, int input_uV,int output_uV, int load_uA); int (* set_suspend_voltage) (struct regulator_dev *, int uV); int (* set_suspend_enable) (struct regulator_dev *); int (* set_suspend_disable) (struct regulator_dev *); int (* set_suspend_mode) (struct regulator_dev *, unsigned int mode); };
MEMBERS
list_voltage
- Return one of the supported voltages, in microvolts; zero if the selector indicates a voltage that is unusable on this system; or negative errno. Selectors range from zero to one less than regulator_desc.n_voltages. Voltages may be reported in any order.
set_voltage
- Set the voltage for the regulator within the range specified. The driver should select the voltage closest to min_uV.
get_voltage
- Return the currently configured voltage for the regulator.
set_current_limit
- Configure a limit for a current-limited regulator.
get_current_limit
- Get the configured limit for a current-limited regulator.
enable
- Configure the regulator as enabled.
disable
- Configure the regulator as disabled.
is_enabled
- Return 1 if the regulator is enabled, 0 if not. May also return negative errno.
set_mode
- Set the configured operating mode for the regulator.
get_mode
- Get the configured operating mode for the regulator.
enable_time
- Time taken for the regulator voltage output voltage to stabalise after being enabled, in microseconds.
get_status
- Return actual (not as-configured) status of regulator, as a REGULATOR_STATUS value (or negative errno)
get_optimum_mode
- Get the most efficient operating mode for the regulator when running with the specified parameters.
set_suspend_voltage
- Set the voltage for the regulator when the system is suspended.
set_suspend_enable
- Mark the regulator as enabled when the system is suspended.
set_suspend_disable
- Mark the regulator as disabled when the system is suspended.
set_suspend_mode
- Set the operating mode for the regulator when the system is suspended.
DESCRIPTION
This struct describes regulator operations which can be implemented by regulator chip drivers.
AUTHORS
Liam Girdwood <lrg@slimlogic.co.uk>
- Author.
Mark Brown <broonie@opensource.wolfsonmicro.com>
Wolfson Microelectronics,
- Author.
COPYRIGHT
Contenus ©2006-2024 Benjamin Poulain
Design ©2006-2024 Maxime Vantorre